Products
Our products
ThermoWhite® Insulation Systems at a glance
The ThermoWhite® products form the core of the system: mineral-bound insulating fills, complemented by coordinated additional products. Together, they enable lightweight, high-performance, and sustainable insulation structures for new construction, renovation, and special applications.
Entdecken Sie die ThermoWhite Anwendungen interaktiv.
Bewegen Sie den Cursor über die Bereiche, um passende Pearls und Produkte anzuzeigen.
Bewegen Sie den Cursor über die Bereiche, um passende Pearls und Produkte anzuzeigen.
ThermoWhite® Insulating Fill
ThermoWhite
WD 70 R (R/N) PREMIUM
- Lambda = 0.0381 W/mK
- Verkehrslasten bis zu 10 kN/m²
- Druckspannung CS(10)50 = > 50 kPa
- For use as thermal and impact sound insulation only. Not suitable for flat roofs or pool backfill.
ThermoWhite WD 100 R
- Using pure recycled granulate
- Very good thermal insulation
- Lambda = 0.046 W/mK
- Verkehrslasten bis zu 10 kN/m²
- Huge impact sound improvement
ThermoWhite WD 130 R
- Using pure recycled granulate
- Very good thermal insulation
- Lambda = 0.055 W/mK
- Verkehrslasten bis zu 20 kN/m²
- Enormous compressive strength
- Compressive strength CS(10)100 = 100 kPa
ThermoWhite WD 170 R A2
- NON-FLAMMABLE (A2-s1, d0)
- Good thermal and impact sound insulation
- Lambda = 0.077 W/mK
- Verkehrslasten bis zu 20 kN/m²
- Compressive strength CS(10)120 = min. 120 kPa
ThermoWhite WD Product Matrix
Mineral-bound EPS insulating fill
| Characteristic | Unit | WD 70 R (R/N) PREMIUM | WD 70 R (R/N) | WD 100 | WD 130 R | WD 170 R A2 | WD 50 R |
|---|---|---|---|---|---|---|---|
| Product type | – | Heat &. Footfall sound. | Heat &. Footfall sound. | Heat &. Footfall sound. | Thermal insulation. (higher load) | Thermal insulation. (higher load) | Exhaust insulation |
| Thermal conductivity (λ) Nominal value (λR) | W/(m·K) W/(m·K) | 0,0381 0,040 | 0,045 0,047 | 0,0464 0,048 | 0,0550 0,057 | 0,073 0,077 | 0,040 NPD |
| Fire behavior | – | E | B-SI | A2-s1,d0 | E | ||
| Dry bulk density | kg/m³ | 70 | 88 | 110 | 145 | 230 | 53 |
| Pressure sensor (CS(10)) | kPa | Greater than or equal to 50 | Greater than or equal to 50 | Greater than or equal to 90 | Greater than or equal to 100 | Greater than or equal to 120 | New Democratic Party |
| Impact sound (Lw) | dB | 25 | 25 | 25 | 25 | New Democratic Party | New Democratic Party |
| Max. load | kN/m² | 10 | 16 | 10 | 16 | 20 | – |
| Diffusion resistance. | μ | 4,5 | 6 | 6 | 6 | 7,1 | 5 |
Explanations & Special Features:
- WD 70 R PREMIUM: Best thermal conductivity (0.0381 W/mK)
- WD 170 R A2 Non-flammable (A2-s1, d0)
Maximum load capacity (20 kN/m²) - WD 50 R Specifically for blown-in insulation. Lowest density, not walkable.
Additional information
- SpeedUp All products can be faster with ThermoWhite® SpeedUp
- Load The maximum traffic load refers to an installation thickness of 10 cm
- NPD No performance determined